      <abstract>
        <p>目的：研究不同保存时长对基层医疗机构血常规自动化检测结果的作
用，为临床检验提供科学的样本保存期限参考，增进检测结果的准确性及临床可
靠性。方法：选取 2021 年 8 月至 2022 年 3 月在我院收集的 86 例血液样本，均
经统一条件下采集，采用同型号全自动血液分析仪进行检测。将标本分别在 0h、
2h、4h、8h 和 24h 进行保存，再对其进行 WBC、RBC、HGB、PLT、HCT、MCV、MPV
等 40 余项血常规参数分析，比较不同时间点的数据差异。结果：0 至 4 小时内，
血液指标稳定，WBC、RBC、HGB、PLT、MCV、MPV 等主要指标变化不显著（P&gt;0.05）。
然而，4 小时后，PLT、WBC 显著下降，8 小时后 RBC、HGB、HCT 也出现明显下降，
且 MPV 和 MCV 有不同程度的升高（P</p>