        <p>本文围绕城市建成区既有校舍在暑期短周期内实施修缮改造的施工特点，对局部基础处理、钢结构停车棚焊接、旧墙面基层治理、屋面防水节点、外立面铝板安装等关键施工技术进行分析。该项目施工范围分散，涉及校园门头、门卫室、停车棚、教学楼内墙、木门、行政楼屋面及墙面等部位。采用分层分段基坑开挖与基底保护措施，保障了地基稳定性。钢结构焊接工艺方面，严格把控焊接参数并实施超声波探伤，保证焊缝质量良好。砖砌体施工时，精确控制灰缝厚度与饱满度，可有效避免结构裂缝。通过科学运用关键施工技术，提高既有校舍安全性能与使用功能，为类似工程提供实践经验，推动既有校舍修缮工程规范化发展。</p>