        <p>加药系统作为大型水厂净水处理的核心环节，其设计合理性直接决定出水水质稳定性、处理成本及运行效率。本文以东莞松山
湖水厂为研究对象，结合当地水源水质特征、水厂设计规模及出水水质标准，从设计背景、原则、核心参数确定、工艺选型、设备配置、
自动控制及安全保障等方面，构建一套适配性强、高效节能的加药系统设计方案。经分析，该方案可实现药剂精准投加，有效提升净水效
果，降低药耗及运维成本，为同类大型水厂加药系统设计提供参考。</p>