<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Article Authoring DTD v1.4 20240229//EN" "JATS-articleauthoring1.dtd">
<article article-type="research-article" xml:lang="zh-CN" xmlns:xlink="http://www.w3.org/1999/xlink">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">58</journal-id>
      <journal-title-group>
        <journal-title>施工技术研究</journal-title>
        <abbrev-journal-title>Research on Construction Technology</abbrev-journal-title>
      </journal-title-group>
      <issn>ISSN: 3104-8129 EISSN: 3104-8137</issn>
      <publisher>
        <publisher-name>睿核出版社有限公司</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65700/RHSGJSYJ01-2511-8129-0373</article-id>
      <article-id pub-id-type="publisher-id">15592</article-id>
      <title-group>
        <article-title>基于一种边缘计算与PLC 智能水务老旧小区的系统研究</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>徐淑云 张耀天 叶文卿</string-name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2025</year>
        <month>8</month>
      </pub-date>
      <issue>8</issue>
      <abstract>
        <p>面向“双碳”战略与老旧小区改造需求，论文构建“边缘计算+PLC+变频泵组”恒压供水系统，
解决高位水箱污染、工频泵高能耗、压力波动大三大痛点。提出“云-边-端”三层两环架构：西门子S7-200
SMART 实现10 ms 级PID 恒压；Edge-Box 融合电-水-振三参数，建立泵健康度指数与多目标最优轮
换模型，故障1 s 切换；云端通过MQTT 进行大数据预测与OTA。核心创新：①“PLC+边缘”双核异
构控制；②“三不”施工法实现2 h 零停水改造；③合同能源管理回收期2.1 年。经936 户、6 个
月运行验证：压力稳态误差≤±0 .015 MPa，节能率32.4 %，可用率99.74 %，年减碳13.3 t。成果
为20 万套老旧小区供水升级提供可复制、低成本、可盈利范式。</p>
      </abstract>
    </article-meta>
  </front>
</article>