      <abstract>
        <p>在超低排放要求限制之下，燃煤电厂烟气净化从单一设备更新升级到系统联合改进。对于湿法脱硫系统存在的流场不均匀以及
气液传质效果差等问题，在吸收塔内开展 CFD 数值仿真计算来研究塔内流场特点以及喷溅传质现象。对导流板设计、喷嘴设置和运行条件
加以改进以达到流速均衡和液滴覆盖率增加的效果，在此基础上提高了脱硫效度同时减少了系统的压降和电耗。证明了 CFD 技术有助于超
低排放改造工程中的精准设计以及运营管理。</p>